Fire System Services carries a wide range of Electic Lithium Battery firefighting equipment, built to exceed the strict requirements of Australian Standards. Product that is reliable and easy to use and maintain – Ranging from fire blankets, and fire extinguishers, to water misty systems stocked and available for dispatch.
As an accredited service provider, Fire System Services is here to assist you with your Electric Lithium Battery Fire Solutions in Adelaide.
An accredited service provider that can assist you with your fire extinguisher sales and services, including Lithium Battery Fire Extinguisher Refills in Adelaide.
They sell and service Various Solutions for Electric Lithium Battery Fires, ranging from Fire Blankets, Fire Extinguishers, Safety Equipment, EV Water Mist Spray Systems, and effective solutions to fight against lithium-metal battery fires.
This makes it an effective solution for extinguishing lithium battery fires.
Safety with Lithium-Ion Battery Fires.
How To Put Out A Lithium Battery Fire
New high-performance battery fire blanket designed explicitly for lithium-ion battery packs.
AVD Fire Ltd has developed a new range of high-performance, multi-use lithium-ion battery fire blankets (“Blankets”) designed specifically for fires involving devices incorporating lithium-ion batteries.
Our Blankets are capable of withstanding extremely high temperatures in an oxidizing atmosphere for a prolonged period and are robust enough to protect against potential debris and shrapnel expelled during a battery fire.
Technical Information
The AVD Fire range of Lithium Battery Fire Blankets uses fire-resistant technical fabrics based on the highest temperature-resistant silica glass fibers.
Flame deflection protection is added to these fibers and abrasion resistance, utilising a variety of proprietary surface coatings.
The non-flammable, vermiculite dispersion mineral–coated glass fabric is overlaid with a sacrificial, protective silicone layer.
No rupture of the fabric after several hours at 1000°C
No break of the fabric after 30 minutes at 1200°C
Fabric becomes brittle after 30 minutes at 1300°C to 1500°C
The LION Fire blanket range has standard sizes from 1m x 1m to 1.8m x 1.8m, which can be used for normal kitchen fires and small lithium-ion battery fires.
This fire blanket meets Australian standards AS/NZS 3504:2006 and EN13501-1:2018 standards.
Additional sizes for various applications, such as 3 x 3m, 3 x 4m & 6 x 8m are also available.
This fire blanket is rated for 550°C with a spike temperature of 750°C. These high-temperature fire blankets are part of Li-Ion Fire Solutions’ expanding range of products designed for lithium-ion battery fires.
Product Specifications
The LION Fire blanket Vehicle Fire Blanket is 6m x 8m, which is an efficient way to isolate and extinguish car fires, even in electric vehicles.
Product Specification
Verification to: EN13501-1:2018
Test to: EN ISO 1182: 2020, EN 13823: 2020 + A1: 2022
The LION Fire, E-Scooter & E-Bike Fire Blanket is 3m x 4m, an efficient way to isolate and extinguish Lithium-Ion batteries commonly found in E-Scooter & E-Bike’s etc.
Verification to: EN13501-1:2018
Test to: EN ISO 1182: 2020, EN 13823: 2020 + A1: 2022
The LION Fire, Mobility Fire Blanket is 5m x 5m, an efficient way to isolate and extinguish Lithium-Ion batteries commonly found in Golf Carts, Mobility Scooters, Ride-On Mowers, Li-Ion Forklifts, Walkie-Stackers etc.
Verification to: EN13501-1:2018
Test to: EN ISO 1182: 2020, EN 13823: 2020 + A1: 2022
The LION Fire Vehicle Fire Blanket is 6m x 8m, which is an efficient way to isolate and contain car fires, even in electric vehicles.
Verification to: EN13501-1:2018
Test to: EN ISO 1182: 2020, EN 13823: 2020 + A1: 2022
Verification to: EN13501-1:2018
Test to: EN ISO 1182: 2020, EN 13823: 2020 + A1: 2022
Wheeled trolley with UV rated plastic cabinet, Suits LION30X40, LION50X50 , EV60X80 Li-ion Fire Blankets.
The Amerex “soft flow” extension applicator is particularly suited for fighting Class D fires. It allows the operator to avoid the extreme heat and toxic fumes caused by burning material.
The easily controlled, even discharge provides a non-dispersing application of the agent.
The extension applicator may be quickly detached to provide a straight stream of chemicals where a more excellent range is required.
MODEL 571 contains a copper extinguishing agent developed by the U.S. Navy for fighting lithium and lithium alloy fires. The copper compound smothers the fire and provides an excellent heat sink for dissipating heat. The copper powder is superior to all other known fire-extinguishing agents for lithium.
These EXTINGUISHERS are pressurised using ARGON. Argon is an inert gas that will not react with combustible metals.
Nitrogen pressurising gas could cause a reaction when used on certain flammable metal fires. Air pressurising SHOULD NEVER be used, as even the slightest amount of moisture will cause a violent response will Class D Materials.
Aqueous Vermiculite Dispersion (AVD) is the first agent proven to combat and extinguish lithium-ion batteries, without reignition.
A unique solution to an otherwise unsolved problem. Adequate lithium-ion battery fire protection designed and tested to tackle the dangers of battery fires across various applications.
The revolutionary extinguishing agent AVD is designed to cool excessive heat and suppress flames in their infancy to help prevent re-ignition and shutdown of fully established fires.
AVD is specifically designed to solve the threat caused by lithium-ion battery fires. Defend against damage and safely control the flames with Lith-Ex AVD, the first lithium-ion battery fire protection choice.
Lith-Ex AVD is a pioneering fire extinguishing agent that has been tried and tested as an adequate lithium-ion battery fire protection.
Lith-Ex AVD fire suppression technology is suitable for use in factories, offices, and other locations with significant lithium-ion battery devices.
Aqueous Vermiculite Dispersion (AVD) – a revolutionary and non-toxic extinguishing agent, is deployed as a mist, which then creates a film over the surface that instantly dries to prevent re-ignition, creates an oxygen barrier, and cools down the flames. The Lith-Ex AVD fire extinguisher works where a powder extinguisher can’t.
The manufacturer has successfully type-tested AVD fire extinguishing agent on a 6.8 kWh battery module.
This equates to a small, domestic solar battery storage system or small hybrid Electric Vehicle with significantly more energy than lithium-ion power tools and electric bicycles.
Aqueous Vermiculite Dispersion (AVD) Lithium Battery fire extinguishing agent is a revolutionary technology that uses fixed and portable delivery techniques to combat lithium-ion battery fires effectively.
Lithium battery failure can be caused by the following:
With the rise in technology that uses lithium batteries, comes the added risk of lithium battery fires. How prepared are you for a lithium battery fire? And are lithium batteries dangerous?
The consequences of lithium battery fires are severe, so having the right precautions in place is critical. AVDfire offers a unique solution that can be used across a range of applications to effectively tackle the blaze.
AVD is an aqueous dispersion of chemically exfoliated vermiculite. It is applied to lithium battery fires as a mist, extinguishing them and preventing the propagation of the fire.
Vermiculite is the name given to a group of hydrated laminar aluminium-iron-magnesium silicates. It consists of thin, flat flakes containing microscopic layers of water. The chemical exfoliation of vermiculite produces microscopic, individual platelets that are freely suspended in water. This yields a stable aqueous dispersion of vermiculite to be used as a lithium battery fire extinguishing agent.
Vermiculite is a naturally occurring mineral that is exempt from REACH regulations. It is chemically and physically inert, only releasing steam when exposed to raised temperatures. It is also non-toxic to humans, plant life, and animals.
The vermiculite particles within the mist are deposited on the surface of the burning fuel to create a film over the top of the fire. The film instantly dries and, because the high aspect ratio platelet particles overlap and bind together, a non-flammable oxygen barrier between the fuel and the atmosphere is produced.
This process has a cooling effect on the fuel source and, as the water content in AVD is evaporated, the vermiculite platelets begin to build up and the fire is brought under control.
The AVD lithium battery fire protection agent is a unique product that provides a solution to an otherwise unsolved problem. AVD’s exceptional performance includes the following:
A Fire Suppression Kit is the perfect solution for effectively controlling and suppressing lithium battery fires. Get results that are unachievable with other fire extinguishing agents.
The kit includes an extinguisher to fight the fire and a bag for the safe suppression and removal of the extinguished device.
The Lith-Ex fire suppression kit is designed to safely store extinguished lithium battery devices while reducing the risk of explosion once the flames have been put out.
The Lith-Ex Fire Suppression Kit includes:
Typical Lith-Ex fire suppression kit applications are mobile phones, tablets, and laptops.
The EVFS system is a fire-fighting device specifically designed for electric vehicles. It comprises a water mist nozzle, Part No. EVFN 01 and an extension pipe, Part No. EVNP 01, both made of stainless steel. The EVFN 01 nozzle is designed to spray water and water mist at low pressures to help cool and extinguish the battery pack under the vehicle chassis. The nozzle measures 79.5mm tall and has a wide spray angle, making it possible to position under most electric vehicle models, with good water spray and water mist coverage.
The EVNP 01 extension pipe allows the EVFN 01 nozzle to be quickly placed under the car chassis. The extension pipe is 1.9 meters long and gives emergency response officers a safe distance to operate. The pipe has two nozzles that spray water mist to cool and extinguish the entry location, hence reducing fire from spreading to nearby vehicles, and protecting rescuers from fire and heat.
According to the Emergency Response Guides from EV manufacturers and the NFPA guidelines, firefighters must apply large amounts of water directly to the battery to stop thermal runaway and extinguish the fire.
Model Number: EVFS
Full Vehicle and Battery Pack Coverage
Effective Spray Area 5.5m x 1.55m at 150mm ground clearance.
Two additional water mist nozzles cover the sides and top of the vehicle up to 1.8m high to help protect emergency responders.
Fast Cooling Effect
combining spray and water misting discharge methods helps absorb heat quickly and efficiently.
Absorb Toxic Gases
The fine water mist can absorb toxic gases produced from the battery chemical reaction.
Multi-Directional Use
with four deployment directions, induced from any side of the vehicle, wide–area coverage to the chassis and side of the vehicle is achievable.
Compact Design
with a compact 79.5mm nozzle height from the ground, it is suitable to slide under all-electric vehicles currently available on the market.
Robust and Durable Design
the entire system is made from 304-grade stainless steel with high-quality surface treatment for strength and durability.
Safe Operating Distance
Providing up to 2.8m safety distance (standard system + one extension pipe) from the burning vehicle coupled with water spray protection, to protect emergency responders from the heat and flames of the burning vehicle.
Quick & Easy Set Up
Self-locking Connections between all main parts for quick setup, deployment, and pack-down.
Insulating Coating
Protects the operator(s) from any potential electric shock risks.
Easy maintenance
a pre-fitted internal filter reduces the chances of blocking nozzles with foreign objects and allows for smooth operation and simple maintenance.
F-500EA Solution Suitable
compatible with F-500 Encapsulator Agent which has been proven to enhance water’s cooling effect by 4-6 times, making this combination incredibly effective on challenging EV Fires.
Fire System Services carries a wide range of Electic Lithium Battery firefighting equipment, built to exceed the strict requirements of Australian Standards. Product that is reliable and easy to use and maintain – Ranging from fire blankets, and fire extinguishers, to water misty systems stocked and available for dispatch.
As an accredited service provider, Fire System Services is here to assist you with your Electric Lithium Battery Fire Solutions in Adelaide.
An accredited service provider that can assist you with your fire extinguisher sales and services, including Lithium Battery Fire Extinguisher Refills in Adelaide.
They sell and service Various Solutions for Electric Lithium Battery Fires, ranging from Fire Blankets, Fire Extinguishers, Safety Equipment, EV Water Mist Spray Systems, and effective solutions to fight against lithium-metal battery fires.
This makes it an effective solution for extinguishing lithium battery fires.
Safety with Lithium-Ion Battery Fires.
How To Put Out A Lithium Battery Fire
New high-performance battery fire blanket designed explicitly for lithium-ion battery packs.
AVD Fire Ltd has developed a new range of high-performance, multi-use lithium-ion battery fire blankets (“Blankets”) designed specifically for fires involving devices incorporating lithium-ion batteries.
Our Blankets are capable of withstanding extremely high temperatures in an oxidizing atmosphere for a prolonged period and are robust enough to protect against potential debris and shrapnel expelled during a battery fire.
Technical Information
The AVD Fire range of Lithium Battery Fire Blankets uses fire-resistant technical fabrics based on the highest temperature-resistant silica glass fibers.
Flame deflection protection is added to these fibers and abrasion resistance, utilising a variety of proprietary surface coatings.
The non-flammable, vermiculite dispersion mineral–coated glass fabric is overlaid with a sacrificial, protective silicone layer.
No rupture of the fabric after several hours at 1000°C
No break of the fabric after 30 minutes at 1200°C
Fabric becomes brittle after 30 minutes at 1300°C to 1500°C
The LION Fire blanket range has standard sizes from 1m x 1m to 1.8m x 1.8m, which can be used for normal kitchen fires and small lithium-ion battery fires.
This fire blanket meets Australian standards AS/NZS 3504:2006 and EN13501-1:2018 standards.
Additional sizes for various applications, such as 3 x 3m, 3 x 4m & 6 x 8m are also available.
This fire blanket is rated for 550°C with a spike temperature of 750°C. These high-temperature fire blankets are part of Li-Ion Fire Solutions’ expanding range of products designed for lithium-ion battery fires.
Product Specifications
The LION Fire blanket Vehicle Fire Blanket is 6m x 8m, which is an efficient way to isolate and extinguish car fires, even in electric vehicles.
Product Specification
Verification to: EN13501-1:2018
Test to: EN ISO 1182: 2020, EN 13823: 2020 + A1: 2022
The LION Fire, E-Scooter & E-Bike Fire Blanket is 3m x 4m, an efficient way to isolate and extinguish Lithium-Ion batteries commonly found in E-Scooter & E-Bike’s etc.
Verification to: EN13501-1:2018
Test to: EN ISO 1182: 2020, EN 13823: 2020 + A1: 2022
The LION Fire, Mobility Fire Blanket is 5m x 5m, an efficient way to isolate and extinguish Lithium-Ion batteries commonly found in Golf Carts, Mobility Scooters, Ride-On Mowers, Li-Ion Forklifts, Walkie-Stackers etc.
Verification to: EN13501-1:2018
Test to: EN ISO 1182: 2020, EN 13823: 2020 + A1: 2022
The LION Fire Vehicle Fire Blanket is 6m x 8m, which is an efficient way to isolate and contain car fires, even in electric vehicles.
Verification to: EN13501-1:2018
Test to: EN ISO 1182: 2020, EN 13823: 2020 + A1: 2022
Verification to: EN13501-1:2018
Test to: EN ISO 1182: 2020, EN 13823: 2020 + A1: 2022
Wheeled trolley with UV rated plastic cabinet, Suits LION30X40, LION50X50 , EV60X80 Li-ion Fire Blankets.
The Amerex “soft flow” extension applicator is particularly suited for fighting Class D fires. It allows the operator to avoid the extreme heat and toxic fumes caused by burning material.
The easily controlled, even discharge provides a non-dispersing application of the agent.
The extension applicator may be quickly detached to provide a straight stream of chemicals where a more excellent range is required.
MODEL 571 contains a copper extinguishing agent developed by the U.S. Navy for fighting lithium and lithium alloy fires. The copper compound smothers the fire and provides an excellent heat sink for dissipating heat. The copper powder is superior to all other known fire-extinguishing agents for lithium.
These EXTINGUISHERS are pressurised using ARGON. Argon is an inert gas that will not react with combustible metals.
Nitrogen pressurising gas could cause a reaction when used on certain flammable metal fires. Air pressurising SHOULD NEVER be used, as even the slightest amount of moisture will cause a violent response will Class D Materials.
Aqueous Vermiculite Dispersion (AVD) is the first agent proven to combat and extinguish lithium-ion batteries, without reignition.
A unique solution to an otherwise unsolved problem. Adequate lithium-ion battery fire protection designed and tested to tackle the dangers of battery fires across various applications.
The revolutionary extinguishing agent AVD is designed to cool excessive heat and suppress flames in their infancy to help prevent re-ignition and shutdown of fully established fires.
AVD is specifically designed to solve the threat caused by lithium-ion battery fires. Defend against damage and safely control the flames with Lith-Ex AVD, the first lithium-ion battery fire protection choice.
Lith-Ex AVD is a pioneering fire extinguishing agent that has been tried and tested as an adequate lithium-ion battery fire protection.
Lith-Ex AVD fire suppression technology is suitable for use in factories, offices, and other locations with significant lithium-ion battery devices.
Aqueous Vermiculite Dispersion (AVD) – a revolutionary and non-toxic extinguishing agent, is deployed as a mist, which then creates a film over the surface that instantly dries to prevent re-ignition, creates an oxygen barrier, and cools down the flames. The Lith-Ex AVD fire extinguisher works where a powder extinguisher can’t.
The manufacturer has successfully type-tested AVD fire extinguishing agent on a 6.8 kWh battery module.
This equates to a small, domestic solar battery storage system or small hybrid Electric Vehicle with significantly more energy than lithium-ion power tools and electric bicycles.
Aqueous Vermiculite Dispersion (AVD) Lithium Battery fire extinguishing agent is a revolutionary technology that uses fixed and portable delivery techniques to combat lithium-ion battery fires effectively.
Lithium battery failure can be caused by the following:
With the rise in technology that uses lithium batteries, comes the added risk of lithium battery fires. How prepared are you for a lithium battery fire? And are lithium batteries dangerous?
The consequences of lithium battery fires are severe, so having the right precautions in place is critical. AVDfire offers a unique solution that can be used across a range of applications to effectively tackle the blaze.
AVD is an aqueous dispersion of chemically exfoliated vermiculite. It is applied to lithium battery fires as a mist, extinguishing them and preventing the propagation of the fire.
Vermiculite is the name given to a group of hydrated laminar aluminium-iron-magnesium silicates. It consists of thin, flat flakes containing microscopic layers of water. The chemical exfoliation of vermiculite produces microscopic, individual platelets that are freely suspended in water. This yields a stable aqueous dispersion of vermiculite to be used as a lithium battery fire extinguishing agent.
Vermiculite is a naturally occurring mineral that is exempt from REACH regulations. It is chemically and physically inert, only releasing steam when exposed to raised temperatures. It is also non-toxic to humans, plant life, and animals.
The vermiculite particles within the mist are deposited on the surface of the burning fuel to create a film over the top of the fire. The film instantly dries and, because the high aspect ratio platelet particles overlap and bind together, a non-flammable oxygen barrier between the fuel and the atmosphere is produced.
This process has a cooling effect on the fuel source and, as the water content in AVD is evaporated, the vermiculite platelets begin to build up and the fire is brought under control.
The AVD lithium battery fire protection agent is a unique product that provides a solution to an otherwise unsolved problem. AVD’s exceptional performance includes the following:
A Fire Suppression Kit is the perfect solution for effectively controlling and suppressing lithium battery fires. Get results that are unachievable with other fire extinguishing agents.
The kit includes an extinguisher to fight the fire and a bag for the safe suppression and removal of the extinguished device.
The Lith-Ex fire suppression kit is designed to safely store extinguished lithium battery devices while reducing the risk of explosion once the flames have been put out.
The Lith-Ex Fire Suppression Kit includes:
Typical Lith-Ex fire suppression kit applications are mobile phones, tablets, and laptops.
The EVFS system is a fire-fighting device specifically designed for electric vehicles. It comprises a water mist nozzle, Part No. EVFN 01 and an extension pipe, Part No. EVNP 01, both made of stainless steel. The EVFN 01 nozzle is designed to spray water and water mist at low pressures to help cool and extinguish the battery pack under the vehicle chassis. The nozzle measures 79.5mm tall and has a wide spray angle, making it possible to position under most electric vehicle models, with good water spray and water mist coverage.
The EVNP 01 extension pipe allows the EVFN 01 nozzle to be quickly placed under the car chassis. The extension pipe is 1.9 meters long and gives emergency response officers a safe distance to operate. The pipe has two nozzles that spray water mist to cool and extinguish the entry location, hence reducing fire from spreading to nearby vehicles, and protecting rescuers from fire and heat.
According to the Emergency Response Guides from EV manufacturers and the NFPA guidelines, firefighters must apply large amounts of water directly to the battery to stop thermal runaway and extinguish the fire.
Model Number: EVFS
Full Vehicle and Battery Pack Coverage
Effective Spray Area 5.5m x 1.55m at 150mm ground clearance.
Two additional water mist nozzles cover the sides and top of the vehicle up to 1.8m high to help protect emergency responders.
Fast Cooling Effect
combining spray and water misting discharge methods helps absorb heat quickly and efficiently.
Absorb Toxic Gases
The fine water mist can absorb toxic gases produced from the battery chemical reaction.
Multi-Directional Use
with four deployment directions, induced from any side of the vehicle, wide–area coverage to the chassis and side of the vehicle is achievable.
Compact Design
with a compact 79.5mm nozzle height from the ground, it is suitable to slide under all-electric vehicles currently available on the market.
Robust and Durable Design
the entire system is made from 304-grade stainless steel with high-quality surface treatment for strength and durability.
Safe Operating Distance
Providing up to 2.8m safety distance (standard system + one extension pipe) from the burning vehicle coupled with water spray protection, to protect emergency responders from the heat and flames of the burning vehicle.
Quick & Easy Set Up
Self-locking Connections between all main parts for quick setup, deployment, and pack-down.
Insulating Coating
Protects the operator(s) from any potential electric shock risks.
Easy maintenance
a pre-fitted internal filter reduces the chances of blocking nozzles with foreign objects and allows for smooth operation and simple maintenance.
F-500EA Solution Suitable
compatible with F-500 Encapsulator Agent which has been proven to enhance water’s cooling effect by 4-6 times, making this combination incredibly effective on challenging EV Fires.