google-site-verification: google199cabc3032d37ab.html
CONTACT US

FXN Rope
Automatic Fire Extinguishing System

About Us

Never worry about your
Electrical Distribution Board Fires Again

 —

Automatic Fire Safety Solution for Enclosures

Fire System Services & BCAi Solutions is proud to serve as the authorized distributor and technical engineering partner for this product in Australia, Singapore, and Malaysia.

The most prevalent defect in residential electrical installations is the insufficient fire protection of switchboards. AS/NZS3000:2018 clause 2.10.7 outlines the fire protection measures necessary to prevent the spread of fire from within switchboards into the building, cavities, and conduits.

Guidance provided under clause 2.10.7 explains how these measures can be implemented.

FireXNull is an innovative fire extinguisher system that utilises nanotechnology through either “sticker” or “rope” applications, providing a cost-effective fire suppression solution designed for electrical enclosures of various sizes.

Leveraging advanced nanotechnology, the FXN Rope integrates the functions of traditional systems into a single product—combining agent storage, detection, and discharge—to ensure complete fire suppression.

Each FXN Rope automatically activates at 428°F (220°C) when exposed to heat, instantly suppressing early-stage fires using an eco-friendly, residue-free clean agent.

Engineered for reliability and requiring no maintenance, this solution is perfect for safeguarding high-risk environments containing valuable equipment.

FXN Rope Applications

Single FXN Rope Sizes Cover Enclosures Up to 70 Cubic Feet (2000 Liters).

• Electrical cabinets and junction boxes
• Data centers and server racks
• Marine and aerospace compartments
• Industrial equipment and control systems
• Automotive industry applications
• Energy Storage System (ESS) enclosures

Its flexible design and advanced technology ensure dependable fire suppression in critical environments.

FXN Rope

Affix the FXN Rope about 2 to 4 inches below the top edge of the object you’re protecting, ensuring it runs parallel.

Promotional Material

The Benefits

  • Automatic fire suppression
  • Non-conductive and residue-free
  • Flexible design for full ignition point coverage
  • Lightweight, easy to install, and maintenance-free
  • Cost-effective and environmentally friendly

How this Works

1. Localised Activation: When a section of the FXN Rope reaches 428°F (220°C), the microcapsules in that area release a clean, non-residue fire-suppressing agent. This agent rapidly vaporises, absorbing heat and effectively extinguishing the fire without leaving residue or causing damage.

2. Thermal Propagation: The FXN Rope also contains potassium nitrate, which, upon activation, decomposes exothermically, generating additional heat. This heat propagates along the rope, triggering adjacent microcapsules to release their fire-suppressing agent, ensuring comprehensive suppression throughout the enclosure.

This combination of localised activation and thermal propagation ensures rapid and effective fire suppression, providing reliable protection for critical environments.

FXN Rope Installation Manual

FXN Rope Installation Instructions

1. Safety Precautions

Ensure the electrical enclosure is completely safe to access, and the electrical power is disconnected before installation.
• Avoid placing the FXN Rope on a hot surface or in an environment where the ambient temperature exceeds 428°F ± 9°F (220°C ± 5°C).
• Handle the FXN Rope with care—do not crush, kink, or cut the rope.
• Wear fireproof gloves when handling the rope to prevent accidental injuries.

2. Preparation

• Ensure the surface inside the enclosure is clean, dry, and free of dust, grease, contaminants, or lubricants.
• Use a lint-free cloth to wipe the surface thoroughly.

3. Mounting Hook Installation

• Peel off the protective paper from the adhesive side of the mounting hooks.
• Press the mounting hooks firmly onto the cleaned surface, ensuring there are no gaps and full adhesion is achieved.
• Maintain a spacing of 6 inches (150mm) between each hook for optimal support.

4. Rope Positioning

Roll the flat tab of the mounting hooks into a semi-circle to match the rope diameter.
• Position the FXN Rope horizontally above potential ignition sources for quicker response time.
• Secure the rope to the mounting hooks using cable ties, ensuring the ties are snug but not overly tight to avoid deforming the rope.

5. Final Steps

Trim any excess length of the cable ties using appropriate cutting tools.
• Inspect the installation for proper alignment and secure fastening.
• Label the installation date and 5-year shelf life (expiration) on the enclosure in a visible location.

6. Maintenance

Regularly inspect the FXN Rope and mounting hooks for signs of wear or damage.
• Replace the FXN Rope every 5 years or immediately after activation.

FXN Rope Introduction
About Us

Never worry about your
Electrical Distribution Board Fires Again

 —

Automatic Fire Safety Solution for Enclosures

Fire System Services & BCAi Solutions is proud to serve as the authorized distributor and technical engineering partner for this product in Australia, Singapore, and Malaysia.

The most prevalent defect in residential electrical installations is the insufficient fire protection of switchboards. AS/NZS3000:2018 clause 2.10.7 outlines the fire protection measures necessary to prevent the spread of fire from within switchboards into the building, cavities, and conduits.

Guidance provided under clause 2.10.7 explains how these measures can be implemented.

FireXNull is an innovative fire extinguisher system that utilises nanotechnology through either “sticker” or “rope” applications, providing a cost-effective fire suppression solution designed for electrical enclosures of various sizes.

Leveraging advanced nanotechnology, the FXN Rope integrates the functions of traditional systems into a single product—combining agent storage, detection, and discharge—to ensure complete fire suppression.

Each FXN Rope automatically activates at 428°F (220°C) when exposed to heat, instantly suppressing early-stage fires using an eco-friendly, residue-free clean agent.

Engineered for reliability and requiring no maintenance, this solution is perfect for safeguarding high-risk environments containing valuable equipment.

FXN Rope Applications

Single FXN Rope Sizes Cover Enclosures Up to 70 Cubic Feet (2000 Liters).

• Electrical cabinets and junction boxes
• Data centers and server racks
• Marine and aerospace compartments
• Industrial equipment and control systems
• Automotive industry applications
• Energy Storage System (ESS) enclosures

Its flexible design and advanced technology ensure dependable fire suppression in critical environments.

FXN Rope

Affix the FXN Rope about 2 to 4 inches below the top edge of the object you’re protecting, ensuring it runs parallel.

Promotional Material

The Benefits

  • Automatic fire suppression
  • Non-conductive and residue-free
  • Flexible design for full ignition point coverage
  • Lightweight, easy to install, and maintenance-free
  • Cost-effective and environmentally friendly

How this Works

1. Localised Activation: When a section of the FXN Rope reaches 428°F (220°C), the microcapsules in that area release a clean, non-residue fire-suppressing agent. This agent rapidly vaporises, absorbing heat and effectively extinguishing the fire without leaving residue or causing damage.

2. Thermal Propagation: The FXN Rope also contains potassium nitrate, which, upon activation, decomposes exothermically, generating additional heat. This heat propagates along the rope, triggering adjacent microcapsules to release their fire-suppressing agent, ensuring comprehensive suppression throughout the enclosure.

This combination of localised activation and thermal propagation ensures rapid and effective fire suppression, providing reliable protection for critical environments.

FXN Rope Installation Manual

FXN Rope Installation Instructions

1. Safety Precautions

Ensure the electrical enclosure is completely safe to access, and the electrical power is disconnected before installation.
• Avoid placing the FXN Rope on a hot surface or in an environment where the ambient temperature exceeds 428°F ± 9°F (220°C ± 5°C).
• Handle the FXN Rope with care—do not crush, kink, or cut the rope.
• Wear fireproof gloves when handling the rope to prevent accidental injuries.

2. Preparation

• Ensure the surface inside the enclosure is clean, dry, and free of dust, grease, contaminants, or lubricants.
• Use a lint-free cloth to wipe the surface thoroughly.

3. Mounting Hook Installation

• Peel off the protective paper from the adhesive side of the mounting hooks.
• Press the mounting hooks firmly onto the cleaned surface, ensuring there are no gaps and full adhesion is achieved.
• Maintain a spacing of 6 inches (150mm) between each hook for optimal support.

4. Rope Positioning

Roll the flat tab of the mounting hooks into a semi-circle to match the rope diameter.
• Position the FXN Rope horizontally above potential ignition sources for quicker response time.
• Secure the rope to the mounting hooks using cable ties, ensuring the ties are snug but not overly tight to avoid deforming the rope.

5. Final Steps

Trim any excess length of the cable ties using appropriate cutting tools.
• Inspect the installation for proper alignment and secure fastening.
• Label the installation date and 5-year shelf life (expiration) on the enclosure in a visible location.

6. Maintenance

Regularly inspect the FXN Rope and mounting hooks for signs of wear or damage.
• Replace the FXN Rope every 5 years or immediately after activation.

Needing Assistance with Fire Safety Solutions In Your Workplace.
CONTACT US NOW